>_TERNUXARM64 / ON-DEVICE LINUX
বাংলা
MENU
HomeDocsAndroid phantom-process controls
TERNUX · DOCUMENTATION

Android phantom-process controls

Optional, system-wide Android controls for PRoot workloads, with Termux ADB, Shizuku rish, computer ADB, verification and rollback steps.

This is an advanced, optional Android host setting for cases where Android's phantom-process policy is confirmed to terminate a Ternux/PRoot workload. It is not a general fix for every SIGKILL, X11 stall, memory-pressure event, or OEM battery restriction. Ternux's doctor is diagnostic; it does not change Android settings.

Android 14 and later may expose Disable child process restrictions in Developer options. Prefer that supported UI control when it exists. The shell commands below are device-wide and OEM/version behavior can differ. Raising the phantom-process ceiling and disabling its monitor weakens Android's protection against excessive background child processes; use them only when needed and keep an eye on memory and battery use.

Choose a shell route

The commands must run as Android's shell user (UID 2000), not as the ordinary Termux app UID. Check the identity before changing anything:

id

The output must include uid=2000(shell). If it shows a Termux app UID such as uid=10490(u0_a490), stop; the shell route is not elevated enough.

Shizuku from Termux

If Shizuku is already running, open its Use Shizuku in terminal apps screen and follow its export/setup instructions for Termux. This provides rish, a Shizuku shell; it does not create an ADB transport or make adb devices show a device. Check it with:

rish -c 'id'

Proceed only when it reports uid=2000(shell). Then run the commands in the next section through rish -c '...' (examples are provided below). Shizuku must be running and Termux must be authorized. Shizuku may need to be started again after reboot. Ternux does not require or install Shizuku, and does not configure it automatically.

ADB from a computer

With USB debugging, authorize that computer on the phone and confirm the device state is device:

adb devices -l

For wireless ADB, enable Wireless debugging in Developer options. On Android 11+, pair once using the displayed pairing address, port, and code, then connect to the separate ADB address and port shown on the Wireless debugging screen:

adb pair PHONE_IP:PAIRING_PORT
adb connect PHONE_IP:ADB_PORT
adb devices -l

Do not expose the wireless debugging port to an untrusted network. On a computer, prefix each command in the next section with adb shell.

ADB client inside native Termux

The Termux package is android-tools:

pkg install android-tools
adb devices -l

An installed ADB client alone does not grant device shell access. A connected, authorized ADB transport is still required. An existing Shizuku session may provide a rish shell without pairing; use the Shizuku route above when that is how the device is managed. A computer connection can instead use adb pair and adb connect as described above.

Record current values and apply

Before changing anything, record the current values so you can restore them:

adb shell /system/bin/device_config get_sync_disabled_for_tests
adb shell /system/bin/device_config get activity_manager max_phantom_processes
adb shell settings get global settings_enable_monitor_phantom_procs

Using the computer ADB route, run the requested commands:

adb shell /system/bin/device_config set_sync_disabled_for_tests persistent
adb shell /system/bin/device_config put activity_manager max_phantom_processes 2147483647
adb shell settings put global settings_enable_monitor_phantom_procs false

persistent disables DeviceConfig synchronization across reboots. That mode is intended for tests and prevents remotely synced DeviceConfig values from overwriting local changes. It is broader than the phantom-process setting and may affect unrelated Android DeviceConfig namespaces. Record its prior value; do not set it blindly on a device where preserving normal DeviceConfig sync is important. Android's accepted modes include none, until_reboot, and persistent.

With Shizuku rish, run the same system commands, omitting the adb shell prefix. For example:

rish -c '/system/bin/device_config set_sync_disabled_for_tests persistent'
rish -c '/system/bin/device_config put activity_manager max_phantom_processes 2147483647'
rish -c 'settings put global settings_enable_monitor_phantom_procs false'

Verify

Run all three checks. The first two should show 2147483647; the last should show false:

adb shell /system/bin/dumpsys activity settings | grep max_phantom_processes
adb shell /system/bin/device_config get activity_manager max_phantom_processes
adb shell settings get global settings_enable_monitor_phantom_procs
adb shell /system/bin/device_config get_sync_disabled_for_tests

For rish, omit adb shell and run the commands via rish -c. A successful write command is not proof that the effective ActivityManager value changed; check both dumpsys and device_config. If a setting is denied, missing, or immediately reverted, stop and use the Android-version-specific Developer options control or vendor guidance. Do not try to bypass OEM protections.

Restore

Restore the exact values recorded before the change. If the phantom-process DeviceConfig key did not exist before, delete the override instead of leaving a new value:

adb shell /system/bin/device_config delete activity_manager max_phantom_processes

If it previously had a value, put that original value back:

adb shell /system/bin/device_config put activity_manager max_phantom_processes ORIGINAL_VALUE

Restore the global monitor setting to its recorded value. If it was absent, remove the override:

adb shell settings delete global settings_enable_monitor_phantom_procs

Restore DeviceConfig sync to its exact prior mode, commonly none:

adb shell /system/bin/device_config set_sync_disabled_for_tests none

Use the same authorized shell route used to apply the changes. Reboot only if Android or the device vendor requires it, then verify the restored values.

Ternux live-device observation

On the maintainer's Android 16 (SDK 36) device, a Termux-native ADB transport was available through the existing Shizuku/watchdog setup. adb shell id reported UID 2000 (shell). The requested values were already present before this check:

  • DeviceConfig sync mode: persistent
  • activity_manager/max_phantom_processes: 2147483647
  • settings_enable_monitor_phantom_procs: false
  • The rish executable was not present in this Termux home; the working device route during this check was the existing ADB transport.

No device value was rewritten. This confirms the values on that device at the time checked; it does not prove that phantom-process killing or X11 stalls are eliminated under every workload.

Related: Troubleshooting · Ternux CLI